Switching Power Supply | NES-150-12 |
|
OUTPUT |
DC VOLTAGE |
12V |
CURRENT RANGE |
0 ~ 12.5A |
|
RATED CURRENT |
12.5A |
|
RATED POWER |
150W |
|
RIPPLE & NOISE (max.) Note.2 |
120mVp-p |
|
VOLTAGE ADJ. RANGE |
11.4 ~ 13.5V |
|
VOLTAGE TOLERANCE NOTE.3 |
1.0% |
|
LINE REGULATION |
0.5% |
|
LOAD REGULATION |
0.5% |
|
SETUP, RISE TIME NOTE.5 |
800ms, 20ms/230VAC 1200ms, 30ms/115VAC at full load |
|
HOLD UP TIME (Typ.) |
24ms/230VAC 20ms/115VAC at full load |
|
INPUT |
VOLTAGE RANGE |
90 ~ 132VAC / 180 ~ 264VAC by switch 254 ~ 370VDC |
FREQUENCY RANGE |
47 ~ 63Hz |
|
EFFICIENCY (Typ.) |
83% |
|
AC CURRENT (Typ.) |
3A/115VAC 2A/230VAC |
|
INRUSH CURRENT (Typ.) |
COLD START 45A/230VAC |
|
LEAKAGE CURRENT |
<2mA / 240VAC |
|
PROTECTION |
OVER LOAD |
110 ~ 150% rated output power |
Protection type : Hiccup mode, recovers automatically after fault condition is removed |
||
OVER VOLTAGE |
13.8 ~ 16.2V |
|
Protection type : Hiccup mode, recovers automatically after fault condition is removed |
||
ENVIRONMENT |
WORKING TEMP. |
-20 ~ +60°C (Refer to output load derating curve) |
WORKING HUMIDITY |
20 ~ 90% RH non-condensing |
|
STORAGE TEMP., HUMIDITY |
-40 ~ +85°C , 10 ~ 95% RH |
|
TEMP. COEFFICIENT |
0.03%/°C (0 ~ 50°C ) |
|
VIBRATION |
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes |
|
SAFETY &EMC(Note 4) |
SAFETY STANDARDS |
UL60950-1, TUV EN60950-1 Approved |
WITHSTAND VOLTAGE? |
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC |
|
ISOLATION RESISTANCE |
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC |
|
EMI CONDUCTION & RADIATION |
Compliance to EN55022 (CISPR22) Class B |
|
HARMONIC CURRENT |
Compliance to EN61000-3-2,-3 |
|
EMS IMMUNITY |
Compliance to EN61000-4-2, 3, 4, 5, 6, 8,11, ENV50204, EN55024, EN61000-6-1, heavy industry level, criteria A |
|
OTHERS |
MTBF |
433.3Khrs min. MIL-HDBK-217F (25 ) |
DIMENSION |
199*98*38mm (L*W*H) |
|
PACKING |
0.7Kg; 30pcs/22Kg/1.24CUFT |
|
NOTE |
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25°Cof ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. Line regulation is measured from low line to high line at rated load. 5. Load regulation is measured from 0% to 100% rated load. 6. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. 7. Length of set up time is measured at cold first start. Turning ON/OFF the power supply very quickly may lead to increase of the set up time. |