Customization: | Available |
---|---|
Output Type: | Single |
Warranty: | >2 Years |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
MODEL |
NES-100-12 | |
OUTPUT | DCVOLTAGE | 12V |
RATEDCURRENT | 8.5A | |
CURRENTRANGE | 0~8.5A | |
RATEDPOWER | 102W | |
RIPPLE&NOISENOTE.2 | 120MVP-P | |
VOLTAGEADJ.RANGE | 11.4~13.2V | |
VOLTAGETOLERANCENOTE.3 | ±1.0% | |
LINEREGULATION | ±0.5% | |
LOADREGULATION | ±0.5% | |
SETUP.RISEHOLD.TIME | 1000ms,20ms/230VAC ,1000ms, 20ms/115VAC at fill load | |
INPUT | VOLTAGERANGE | 85 ~ 132VAC / 176 ~ 264VAC selected by switch 248 ~ 373VDC |
FREQUENCYRANGE | 47~63HZ | |
EFFICIENCY | 83% | |
AC CURRENT | 2a/115vac 1.2a/230vac | |
INRUSH CURRENT | Cold start 45A | |
LEAKAGECURRENT | <2mA/240VAC | |
PROTECTION | OVERLOAD | 110~150%rated output power |
Protection type:Hiccup mode,recovers automatically after r fault condition is removed | ||
OVER VOLTAGE | 13.8~16.2V | |
Protection type: Hiccup mode, recovers automatically after fault condition is removed | ||
ENVIRONMENT | WORKING TEMP | -20~+60ºC(Refer to "Derating Curve") |
WORKING HUMIDITY | -20~90%Rhnon-condensing | |
STORAGE TEMP HUMIDITY | -40~+85ºC 10~95%RH | |
TEMPCOEFFICIENT | ±0.03%(0~45ºC) | |
VIBRATION | 10~500HZ,2G10min/1cycle period for 60 min each alongX,Y,Zaxes | |
SAFETY&EMC | SAFETYSTANDARDS | UL60950-1 Approved,CB Approved by TUV(design Refer to IEC 60950-1) |
WITHSTAND VOLTAGE | 1/P-0/P:3KVAC 1/P-FG:1.5KVAC 0/P-FG:0.5KVAC | |
ISOLATIONRESISTANCE | 1/P-0/P,1/P-FG,0/P-FG:100M Ohms/500VDC | |
EMI CONDUCTICN& RADIATION |
Compliance to EN55022(CISPR22)classB | |
HARMONICCURRENT | Compliance to EN61000-3-2,-3 |